top of page
ECOLOG TH1
  • Data logger for T / RH

  • High-precision instrument 
    ± 1.5% RH, ± 0.2 °C

  • Reliable and proven design

  • Additionally combined temperature / humidity probe

  • User exchangeable probe

Brochure

Measurement parameters:                               Temperature
                                                                               Temperature, relative humidity

 

Monitoring tasks:                                                 Equipment
                                                                               Room
                                                                               Container
                                                                               Process

 

Application range:                                              RT / Ambient [+2 °C..+25 °C]
                                                                              Warm [+37 °C..+70 °C]

 

Measurement range:                                         Internal sensor: -35 °C..+55 °C and 
                                                                              0% RH..100% RH
                                                                              External temperature / humidity probe: 
                                                                              -35 °C..+70 °C and 0% RH..100% RH 
                                                                              External NTC probe: -55 °C..+140 °C

 

Accuracy:                                                            Temperature:
                                                                              ±0.2 °C [+0.1 °C..+30.0 °C]
                                                                              ±0.3 °C [-24.9 °C..-0.0 °C] and [+30.1 °C..+70.0 °C]
                                                                              ±0.4 °C [-50.0 °C..-25.0 °C] and 
                                                                              [+70.1 °C..+100.0 °C]
                                                                              ±0.7 °C [+100.1 °C..+140.0 °C]

                                                                              Relative humidity:
                                                                              ±1.5% RH at +23 °C

 

Memory capacity:                                              32'000 measurement values per channel

 

Alarm:                                                                   On display
                                                                              External

 

Part no:                                                                800440

 

Connectivity:                                                      Local / not networked

 

Number of channels:                                       2

bottom of page